Standard Fan Coils

Typical single-evaporator chilled water fan coil features:
• Precision-engineered 16-gauge anodized aluminum chassis, drain pan and evaporator housing are lightweight and corrosion   resistant.
• Drain pan under the evaporator only. This results in a dry chassis and no condensate sloshing.
• Engineered hat-section reinforcing plat provides exceptional strength and lightweight
• Incredibly rugged and simple over-the-counter components in and electric box – no proprietary, expensive printed circuit   boards.
• Whisper-quiet Dayton split-pole blower motors, absent the humming sounds of variable speed DC motors.

Model BTUs of cooling KW of elec. heat Length in inches/mm Width in inches/mm Height in inches/mm Amps (cool) 115/230 Amps (electric heat) 115/230 Weight lbs/kg
FM9CWFC 9,000 1.7 15.5/394 12/305 12/305 1.9/.95 17/8.5 26/12
FM12CWFC 12,000 2.0 15.5/394 13/331 14/356 2.3/1.2 19.5/9.75 36/17
FM16CWFC 16,000 2.0 15.5/394 13/331 14/356 2.3/1.2 19.5/9.75 36/17
FM24CWFC 24,000 4.0 20.5/521 15.5/394 18/458 3.2/1.6 20-230v 81/37
FM36CWFC 36,000 4.0 21.5/547 16/407 19.5/496 3.2/1.6 20-230v 113/52
FM48CWFC 48,000 6.0 26.5/673 28/712 26/661 4.1-230v 28-230v 130/59
FM60CWFC 60,000 8.0 26.5/673 28/712 26/661 5.1-230v 37-230v 163/74
FM72CWFC 72,000 10.0 26.5/673 28/712 26/661 5.2-230v 46-230v 201/92
FM96CWFC 96,000 10.0 49.25/1251 32/813 27/686 6.4-230v 49-230v 257/117
FM120CWFC 120,000 16.0 49.25/1251 32/813 27/686 7.9-230v 72-230v 341/155

Low Profile Enclosed Fan Coils

Model BTUs of cooling KW of elec. heat Length in inches/mm Width in inches/mm Height in inches/mm Amps (cool) 115/220 Amps (elec.heat) 115/220 Weight lbs/kw
FM9CWFC-LP-EN 9,000 1.7 17.0/432 14.5/368 9.0/229 1.9/.95 17/8.5 26/12
FM12CWFC-LP-EN 12,000 2.0 17.0/432 14.5/368 9.0/229 2.3/1.2 19.5/19.75 36/17
FM16CWFC-LP-EN 16,000 2.0 17.0/432 14.5/368 9.0/229 2.3/1.2 19.5/19.75 36.17
FM24CWFC-LP-EN 24,000 4.0 35.25/895 14.5/368 12.5/318 3.2/1.6 20-230v 81/37
FM36CWFC-LP-EN 36,000 4.0 35.25/895 14.5/368 12.5/318 3.2/1.6 20-230v 113/52

Digital controls are extra. Prices FOB Stuart, Florida, USA - Add 6.5% sales tax if shipped to a Florida address - all voltages and triple phase available for additional fee - call for details. Totally aluminum enclosed units add 25%.

Optional Heat

The optional heat can be one of our legendary incoloy clad electric elements in the fan coil (shown), an in line oil fired boiler, an electric element in the chiller, or reverse cycle. We prefer the electric elements in the fan coils because the entire system is shut down when in the heating season – the only moving part is the blower motor when heat is called for. We have had tens of thousands of these elements in service for many years – they are extremely safe and basically indestructible.